Products Description
Metal structures buried deep underground or immersed in water — electrochemical corrosion continuously erodes pipe walls and steel structures like an undercurrent. The very purpose of the smart potentiostat is to fight electricity with electricity — using precise current output to offset the corrosion tendency and keep the metal surface always in the safe potential range. With the reference electrode as its sensing antenna, the equipment captures potential fluctuations in real time, adjusts the output immediately through the internal closed-loop control system, and firmly locks the protective potential within the preset threshold. The entire adjustment process is automated, with a response speed far exceeding manual judgment, while accuracy and stability improve simultaneously.
The smart potentiostat developed by Shandong AOKE Anticorrosion Engineering Co., Ltd. integrates four control modes — constant potential, constant current, constant voltage and constant OFF potential — to meet protection needs under different operating conditions. Relying on 4G wireless networks or fiber-optic wired links, the equipment synchronously uploads key parameters such as operating voltage, load current and real-time protective potential to the remote management platform, allowing technical personnel to complete parameter setting and operating status inspection without going to the site. For long-distance transmission pipelines stretching hundreds of kilometers, this remote management capability brings scattered cathodic protection stations together into a uniformly dispatched intelligent network.
Field environments are often accompanied by strong electromagnetic interference such as thunderstorms and the start-stop of high-power equipment, and the protection and fault tolerance capability of the potentiostat is directly related to the survival of the cathodic protection system. The smart potentiostat adopts modular power units, and the output capacity can be flexibly selected according to the project scale; multi-stage lightning protection circuits and anti-interference filters are configured in combination to effectively suppress lightning surges and power-frequency crosstalk, ensuring a stable and clean output waveform. The equipment has built-in multiple safety mechanisms such as overcurrent self-locking, over-temperature protection and fault self-diagnosis, and combined with the interlocked switching between the main unit and the standby unit, provides uninterrupted operation guarantee for core stations. When the output potential deviates from the set window, the equipment immediately triggers an audible and visual alarm; if the constant potential control loop fails, the system automatically switches to constant current mode to continue running, avoiding the risk of protection interruption.
In terms of control accuracy, the output voltage and current of the equipment can both be continuously adjusted over a wide range, and potential drift during long-term operation is suppressed within the millivolt level. Standardized RS485 and Ethernet interfaces allow it to quickly integrate into various intelligent monitoring systems, with no restrictions on deployment and expansion.
With a highly reliable hardware architecture and intelligent control logic, the smart potentiostat provides all-weather core support for cathodic protection of long-distance oil and gas pipelines, large storage tanks and port steel piles.
The technical parameters and applicable standards of the smart potentiostat are as follows:
1. Technical Parameters
The following are the main performance parameters of the smart potentiostat:
1. Cabinet dimensions: standard dimensions 600×600×800 and 800×800×2100; custom sizes can also be produced to customer requirements.
2. Power supply: optional AC220V 50Hz or AC380V 50Hz.
3. Insulation resistance: the insulation resistance between each input/output terminal and the enclosure is ≥10MΩ.
4. Dielectric strength: the AC power input terminals, relative to the enclosure, and the "zero-connection (cathode)" terminal of the equipment, relative to the output terminals of each remote interface, shall withstand a test voltage of 1500V (RMS) at 50Hz for 1 minute without flashover or breakdown; the DC power input terminals, relative to the enclosure, shall withstand a test voltage of 750V (RMS) at 50Hz for 1 minute without flashover or breakdown.
5. Protection functions:
· Lightning protection: built-in multi-stage lightning protection units. When the anode line or the pipeline is affected by induced lightning, the clamping voltage is 100-150V with a discharge capacity of 20kA; between the reference line and the zero-connection (cathode) terminal, the clamping voltage is 5V with a discharge capacity of 5kA.
· Overcurrent protection: when the output current reaches 102%-110% of the rated value, the output is automatically cut off or current-limited, with an audible and visual alarm, and can automatically recover after a delay.
· Over-temperature protection: built-in intelligent temperature-controlled radiator; the equipment automatically shuts down for protection when the temperature exceeds the limit.
· Fault protection: in the event of a fault, the yellow indicator lights up and an alarm is issued; the working unit and standby unit have an interlock function.
6. Cooling method: optional air-cooled or oil-cooled.
4. Measurement and display: parameters such as output voltage, output current, protective potential and power supply voltage are displayed digitally.
8. Terminals: equipped with terminals for power input, anode output, cathode output, zero-connection (cathode), reference input, polarization coupon and enclosure grounding.
9. Output range: output voltage adjustable range 2%UdN (V) ~ 100%UdN (V); output current adjustable range 2%IdN (A) ~ 100%IdN (A).
10. Constant potential control range: +100mV ~ -3.000V.
11. Operating modes: supports four modes: constant potential, constant current, constant voltage and constant OFF potential.
12. Anti-interference capability: when a 50Hz, 30V interference voltage is applied between the "reference electrode" and "zero-connection (cathode)" terminals, the change in protective potential is no greater than 5mV.
13. Deviation alarm function: when the ON potential deviates from the control potential by 30mV~100mV, an audible and visual alarm can be issued.
14. Automatic conversion function: when constant potential operation is not possible, it can automatically convert to constant current operation.
15. Constant current setting range: continuously adjustable within 2%IdN ~ 100%IdN.
16. Drift characteristics: during continuous operation under rated conditions, the change in ON potential is less than 5mV.
17. Data transmission and control: remote data transmission and control can be achieved through 4G wireless networks or wired communication; in coordination with the cathodic protection online monitoring system, system data is transmitted through RS485 interfaces or Ethernet ports.
18. Coupon interruption function: equipped with an internal coupon interruption switch, it can measure the OFF potential and run the smart constant OFF potential function.
2. Applicable Standards
Reference standard: SY/T 7326-2016 General Technical Specification for Potentiostats