Cathodic protection is a type of electrochemical protection technology. Its core is not simply “energizing the metal.” Instead, through sacrificial anodes or impressed current, cathodic current is supplied to the protected metal, causing cathodic polarization and a negative potential shift of the metal, thereby suppressing the anodic dissolution reaction in which the metal loses electrons, and thus avoiding or mitigating corrosion. For buried steel pipelines, cathodic protection is normally applied in combination with anti-corrosion coatings. The coating isolates most of the soil environment, while cathodic protection mainly protects coating holidays, damaged areas, and uncoated sections.
Core Definition
Cathodic protection technology belongs to electrochemical protection technologies. Its working principle is as follows: the protected metallic structure is used as the cathode. Cathodic current is supplied to the metal-electrolyte interface through sacrificial anodes or impressed current, producing cathodic polarization on the surface of the protected metal and shifting its potential negatively into the protection potential range. As a result, the original anodic reaction on the metal surface — iron losing electrons and becoming iron ions — is significantly suppressed, and the corrosion rate decreases accordingly.
It should be emphasized that cathodic protection is more than simply “making the whole pipeline the electron-accepting side.” More precisely, it makes the pipeline surface into a cathode, with external current flowing into the pipeline, leading to electron accumulation on the metal surface and inhibiting iron from losing electrons. Cathodic protection cannot completely replace anti-corrosion coatings; the combined application of both provides higher cost-effectiveness and reliability.
Causes of Metal Corrosion
Buried steel pipelines are not surrounded by dry insulators, but by a soil electrolyte containing moisture, salts, oxygen, and other substances. Due to material inhomogeneity, variations in soil resistivity, differences in oxygen content, stray current, and other factors, numerous microscopic corrosion galvanic cells form on the steel pipe surface. Regions with more negative potential and higher activity act as anodes, where oxidation reactions occur:
Fe → Fe²⁺ + 2e⁻
Iron atoms lose electrons and become iron ions that diffuse into the soil, gradually thinning the pipe wall. Electrons flow toward cathode zones, where reduction reactions take place, for example:
O₂ + 2H₂O + 4e⁻ → 4OH⁻
Essentially, corrosion is the process of iron losing electrons in anode zones. If electrons are supplemented to the pipeline through external measures to achieve overall cathodic polarization of the pipeline surface, the tendency of iron to lose electrons will be suppressed, and corrosion will be weakened or even stopped. This is the fundamental logic of cathodic protection.
Two Implementation Methods of Cathodic Protection
There are two main methods for implementing cathodic protection.
The first is the sacrificial anode method. More active metals with more negative potential, such as magnesium alloy, zinc alloy, and aluminum alloy, are used as sacrificial anodes and connected to the protected metal through conductors. Sacrificial anodes corrode preferentially and release electrons, which flow through the conductors to the protected metal. Current flows from the anodes through the soil to the protected metal, bringing the protected metal to a relatively negative potential and causing it to act as the cathode. The sacrificial anode method does not require an external power supply, has simple construction, and generally causes little interference to adjacent structures. It is suitable for small-scale, scattered metallic structures or environments with low soil resistivity. Its disadvantages include limited output current and anode consumption, which requires periodic anode replacement.
The second is the impressed current method. It uses a DC power supply provided by a Smart Potentiostat or rectifier. The positive terminal of the power supply is connected to the auxiliary anode groundbed, and the negative terminal is connected to the protected pipeline. Current flows from the auxiliary anode through the soil to the pipeline, then returns along the pipeline and cables to the negative terminal of the power supply, making the entire pipeline surface a cathode. The impressed current method has a large and adjustable output current and is suitable for long-distance, large-diameter pipelines and environments with high soil resistivity. Its disadvantages include dependence on an external power supply, high design and maintenance requirements, and potential stray current interference to nearby metallic structures.
Functions of Cathodic Protection
Cathodic Protection mainly serves three functions. First, it extends the service life of the pipeline. By suppressing electrochemical corrosion, it reduces pipeline perforation and leakage incidents and improves operational reliability. Second, it ensures safe production. Corrosion-induced perforation of oil and gas pipelines and storage tanks may lead to catastrophic accidents such as fire and explosion, and cathodic protection can significantly reduce such risks. Third, it reduces operating costs. A lower corrosion rate reduces the frequency of repairs and replacements, thereby decreasing the whole-life cost. In addition, cathodic protection is also widely used for steel wharf piles, underground storage tanks, urban gas pipelines, and other metallic structures.
Relevant Standards
GB/T 21448-2017 Technical Specification for Cathodic Protection of Buried Steel Pipelines specifies the minimum technical requirements for the design, construction, testing, management, and maintenance of cathodic protection systems for the external surfaces of on-land buried steel pipelines. It applies to on-land buried steel oil, gas, and water pipelines. In practical engineering, a comprehensive evaluation should be carried out in consideration of coating conditions, soil environment, stray current conditions, and protection potential test results. Normally, the pipeline should reach the specified protection potential, for example, −850 mV or more negative relative to a copper/copper sulfate reference electrode. However, over-protection should be avoided to prevent coating disbondment, hydrogen embrittlement, and other problems.